uniFLOW or Universal Login Manager Integration |
Scroll |
To benefit from uniFLOW or Universal Login Manager functionality in your Thereforeā¢ system, configure as detailed below.
Version Requirements
uniFLOW:
Canon imageRUNNER ADVANCE devices require uniFLOW server version 4.0.5 or later and uniFLOW Login Manager jar file version 2.4.0 or later.
Universal Login Manager:
Canon imageRUNNER ADVANCE devices require uniFLOW server version 5.2 or later and Universal Login Manager version 4.0.2 or later.
•Universal Login Manager: The Universal Login Manager must run in uniFLOW server mode in order to automatically log in to Thereforeā¢. Please see NT-ware documentation here.
•If the Universal Login Manager is NOT in uniFLOW server mode, automatic login to Thereforeā¢ is not possible. In this case, the "Login Manager" setting of the Therefore MFP Application must be set to "Ignore Login Manager" in the Solution Designer. Please refer to the Administration Manual for further details on changing these settings. |
1.Install and configure the Thereforeā¢ MFP Application.
2.In the file "PublicKey.txt", which can be found in the Thereforeā¢ installation folder, there is a modulus and an exponent in a similar format to that shown below.
<Modulus>b31b20dfe6604fc8ceef7acea653691015</Modulus><Exponent>010001</Exponent>.
3. Configure uniFLOW server using the modulus and exponent from "PublicKey.txt". See NT-ware documentation here.